Water conductivity: the ions behind the measurement
Water conductivity remains greater than zero even in chemically pure water. NIST's 2004 publication on conductivity standards calculates a value of 0.055 microsiemens per centimeter for pure water at 25 degrees Celsius. It contrasts that theoretical value with about 1.05 microsiemens per centimeter for water equilibrated with atmospheric carbon dioxide. The difference is chemical: carbon dioxide dissolves and produces ions that contribute to electrical conduction. A sample can therefore change electrically simply through contact with the air.
The small starting conductivity comes from water itself. As described in OpenStax's treatment of acid-base chemistry, one water molecule can transfer a proton to another, producing hydronium and hydroxide ions. The reversible process, autoionization, leaves equal concentrations of the two ions in pure water. At 25 degrees Celsius, each concentration is approximately 0.0000001 moles per liter. Most molecules remain uncharged. Heating changes the equilibrium: at 80 degrees Celsius, each concentration rises to about 0.00000049 moles per liter. Those figures describe chemically pure water under specified conditions, rather than a universal concentration for every glass or stream. Low conductivity is consequently different from a complete absence of charge carriers.
Ordinary water acquires additional dissolved material. The US Geological Survey's Water Science School describes salts as combinations of positive cations and negative anions. Table salt supplies the familiar example of sodium and chloride. When both are present, their charges can balance so that the solution has no overall electrical charge. Electrical neutrality nevertheless does not prevent the individual ions from moving and carrying current. USGS notes that even distilled or deionized water can retain ions, and that its scientists commonly measure conductivity when collecting samples. The conductivity cell records a property of the water with its dissolved constituents, rather than of an isolated water molecule.
A USGS photograph places the same chemistry in the Frio River, Texas, where employees are electrofishing. The agency describes using current to collect fish for examination and then returning them to the stream. That sampling method depends on the dissolved salts that permit current to pass through the river water. The ions have a practical effect even when the purpose of the fieldwork is studying fish.
The contrast between ionic and molecular solutes makes the mechanism visible. OpenStax's electrolyte discussion compares potassium chloride, ethanol, and acetic acid solutions. Dissolved potassium chloride supplies freely moving potassium and chloride ions and conducts strongly. Ethanol dissolves as neutral molecules, so its solution does not acquire a comparable population of ions from the solute. Acetic acid produces ions only partly and conducts more weakly. The distinction is between the charged particles formed in solution, rather than whether a substance visibly dissolves. Polar water molecules surround the potassium and chloride ions and weaken the attractions holding the solid together. Their oxygen ends orient toward positive ions and their hydrogen ends toward negative ions, allowing the hydrated ions to disperse. This explains why simply counting dissolved molecules would miss the factor controlling water conductivity.
NIST's standards turn that chemical behavior into a reproducible measurement. Resistance is measured in a conductivity cell, and the cell constant captures the relationship between the electrode spacing and effective cross-sectional area. Conductivity is calculated from that constant and the measured resistance. Calibration compares the cell with solutions of known conductivity. The 2004 publication describes primary standards and the transfer of their values to reference materials, rather than assuming that any meter reading is automatically accurate. Cleaning, temperature control, and absorbed carbon dioxide are identified as experimental influences. Water conductivity depends on what is in the sample, but its reported value also depends on how the measurement is made.
EPA's archived stream-monitoring procedure shows how the same property becomes useful outside the laboratory. Streams passing through relatively inert granite tend to acquire fewer ions than streams crossing materials that ionize more readily. Groundwater entering a channel carries the effects of the bedrock through which it has traveled. Temperature also changes the reading, so measurements are commonly reported for a reference temperature of 25 degrees Celsius. A comparison between sites or sampling dates needs that common basis. The agency describes conductivity as a general indicator of changing stream chemistry, rather than an identification of each dissolved substance.
The practical procedure calls for a standard solution, usually potassium chloride or sodium chloride, chosen for the expected measuring range. The probe is rinsed with distilled or deionized water before the sample is measured. EPA also gives an empirical factor between 0.55 and 0.9 for estimating dissolved-solids concentration from conductivity, rather than one universal conversion. Composition affects the relationship. A change in water conductivity can flag altered conditions, but it cannot specify which ions have arrived or assign the change to a single source. The electrical measurement gains its meaning from the sample's chemistry, the calibration, and comparison with the stream's established range.
- R. H. Shreiner and K. W. Pratt, NIST Special Publication 260-142, 2004 edition: Primary Standards and Standard Reference Materials for Electrolytic Conductivity — www.nist.gov
- OpenStax, Chemistry 2e, 14.1 Brønsted-Lowry Acids and Bases — openstax.org
- US Geological Survey, Conductivity (Electrical Conductance) and Water — www.usgs.gov
- OpenStax, Chemistry 2e, 11.2 Electrolytes — openstax.org
- US Environmental Protection Agency, 5.9 Conductivity: archived stream-monitoring procedure — archive.epa.gov